Perform Hydraulic Oil Analysis; Inspect The Fuel And Hydraulic Tank Cap Venting Systems - Genie GTH-1048 Service Manual

Serial number range from gth1007a-11443 to gth1009a-14000/from gth1007b-7101 to gth1007b-7251
Hide thumbs Also See for GTH-1048:
Table of Contents

Advertisement

March 2016
B-6 Per form Hy draulic Oil Analysis
B-6

Perform Hydraulic Oil Analysis

Genie specifications require that this procedure be
performed every 250 hours or quarterly, whichever
comes first.
Replacement or testing of the hydraulic oil is
essential for good machine performance and
service life. Dirty oil and a clogged suction strainer
may cause the machine to perform poorly and
continued use may cause component damage.
Extremely dirty conditions may require oil changes
to be performed more often. For hydraulic oil
specifications, Refer to Specifications, Hydraulic
Specifications.
Note: Before replacing the hydraulic oil, the oil may
be tested by an oil distributor for specific levels of
contamination to verify that changing the oil is
necessary. If the hydraulic oil is not replaced at the
two year inspection, test the oil quarterly. Replace
the oil when it fails the test. Refer to Maintenance
Procedure, Test or Replace the Hydraulic Oil.
Part No. 123701
Checklist B Procedures
B-7 Ins pect the F uel and Hy draulic T ank C ap Venting Systems
B-7
Inspect the Fuel and Hydraulic
Tank Cap Venting Systems
Genie specifications require that this procedure be
performed every 250 hours or quarterly, whichever
comes first.
Perform this procedure more often if dusty
conditions exist.
Free-breathing fuel and hydraulic tank caps are
essential for good machine performance and
service life. A dirty or clogged tank cap may cause
the machine to perform poorly and continued use
may cause component damage. Extremely dirty
conditions may require that the caps be inspected
more often.
Note: Perform this procedure with the engine off.
1
Remove the fuel filler cap from the tank.
2
Check for proper venting.
Result: Air passes through the fuel tank cap.
Proceed to step 4.
Result: If air does not pass through the cap,
clean or replace the cap. Proceed to step 3.
Note: When checking for positive tank cap venting,
air should pass freely through the cap.
GTH-1048 • GTH-1056
Service Manual
Explosion and fire hazard.
Engine fuels are combustible.
Perform this procedure in an
open, well-ventilated area away
from heaters, sparks, flames and
lighted tobacco. Always have an
approved fire extinguisher within
easy reach.