COMPLETING HEATER INSTALLATION
ATTACHING DRESS GUARD TO CLASSIC FASCIA ASSEMBLY
A
The mesh dress guard of the classic model fascia is held in place by four slotted tabs (two on each side)
lock into four slots
B
ABNORMAL FLAME PATTERN
Each Rinnai Flame Fire heater has a distinct flame pattern. The flame should look
the same every time you start your heater, after an initial warm up period of
approximately 15 minutes.
Abnormal flame performance and/or pattern can indicate a problem with your
heater, such as blocked gas injectors, incorrectly installed / inadequate flue system
or the artificial logs/burn media may have shifted from when the heater was first
installed.
There are some warning signs that could indicate a problem. If any of the signs
below occur, please contact Rinnai.
Key signs of Abnormal flame performance:
• Appliance turns 'OFF' soon after start up and does not relight.
• Flame appears overly orange-yellow.
• Flame appears either very short or very long.
• Flame only burns part way across the burner.
• Severe soot building up on the inside of the glass and logs.
• Continuous unusual smell from the appliance.
• Continued difficulty or delay in establishing a flame.
Be advised that appliances incorporating a live fuel effect, and
designed to operate with luminous flames, may exhibit slight carbon
NOTE
deposition, this is normal operation.
Candling Flames - Propane and ULPG appliances
Particular care of granular placement must be observed when setting up on Propane or ULPG. In
NOTE
the event of a long candle like flame developing the granular media will need to be carefully
positioned to cover the offending burner port enough to diffuse the flame.
Rinnai
B
A
on the front of the fascia.
B
46
which
A
NORMAL FLAME PATTERN
ABNORMAL FLAME PATTERN
CANDLING FLAMES
SOOT BUILD UP