5. Press the 'Set Button'
stage 7).
6. Press the 'UP' button
or when the desired pressure is achieved press the 'Set Button'
7. The display
, will now show
13
and the pressure setting procedure should be repeated from step 1 onward after turning the appliance 'OFF'
8. With the display
13
9. Setting main burner pressure is now complete. Remove the manometer hose and replace the inlet test point
screw
. Check for leaks using soapy water solution.
1
Step 7 . Checking and setting Pilot burner pressure.
1. Remove the pilot burner gas test point screw
2. Press the heater ON/OFF button
3. Press the 'TEST' button
its lowest setting, (Main burner - stage 1), and the display
4. Adjust the pilot burner gas pressure to the value for the gas type as listed in the table below via the 'Pilot
Buner Pressure Adjustment' screw
Pilot Burner Pressure
5. Press the heater ON/OFF button
and replace the pilot burner gas test point screw
6. Check for gas leaks using soapy water, setting or checking pilot burner pressure is now complete.
The Requirements of AS / NZS 5601 include:
a. checking whether mechanical extraction ventilation draws air through flue systems or
NOTE
chimneys or not. If yes, this will most likely result in combustion product spillage from
appliances during their operation.
b. checking whether the operation of appliances and flue systems or chimneys is satisfactory.
c. a method for determining the additional fixed ventilation area required to counteract the
effect of mechanical extract ventilation.
Always check gas pressure values against those recorded on this appliances data plate, values on
the data plate override values printed in this instruction.
WARNING
Spillage tests and countermeasures (when required) are critical for safe operation of the appliance.
Spillage can be detected at the downdraft diverter relief openings located at the front and on the
WARNING
sides of the appliance, as shown to the below. If unsure contact Rinnai for advice.
Rinnai
COMMISSIONING INSTRUCTIONS
, once to save the setting. The display
11
or 'DOWN' button
8
. If the display does not change to
, showing
Press the heater ON/OFF button
to start the ignition sequence, the appliance will ignite normally.
12
, twice on the PCB control panel, the igniter will spark and the appliance will light to
6
.
3
Natural Gas
1.00 kPa
, once to stop the appliance operation. Disconnect the manometer hose
12
, should now be displaying
13
to adjust to the required value, If the pressure is already correct
9
, once to save the setting.
11
, and connect a positive pressure manometer hose.
2
, will show
13
Propane Gas
2.00 kPa
.
2
TEST BOTH
SIDES
43
there was an error in pressure setting
.
12
.
Refer to this table for the correct gas
settings, noting that data plate values
override the values printed in this instruction!