Safety Devices - Rinnai RIB2312L Operation & Installation Manual

Sapphire gas log flame fire
Hide thumbs Also See for RIB2312L:
Table of Contents

Advertisement

A dedicated 230V earthed 10 Amp power point must be used with this appliance.
DO NOT use power boards or double adaptors to operate this appliance. The heater MUST NOT be located below
a power socket-outlet.
DO NOT place containers of liquid on top of the heater. Water spillage can cause extensive damage to the
appliance and create an electrocution hazard.
DO NOT place articles on or against this appliance.
DO NOT CONNECT TO AN LPG GAS CYLINDER INDOORS.
Turn the heater 'OFF' after use.
DO NOT unplug the heater while it is in operation or while the fan is still cycling.
DO NOT remove the Dress Guard. The dress guard is fitted to this appliance to reduce the risk of fire or injury from
burns and no part of it should be permanently removed. For protection of children or the infirm, a secondary guard
is recommended.
Heat emanating from the front of the appliance may over time affect the appearance of some materials used for
flooring such as carpet, vinyl, cork or timber. This affect may be amplified if the air in the room contains cooking
vapours or cigarette smoke. To avoid this possibility, it is recommended that a mat be placed in front of the
appliance, extending at least 750 mm in front of the heater.
When the heater is operated for the first time or after long periods of non use a slight odour may be emitted, this is
normal. However if odours persist switch 'OFF' the appliance and contact Rinnai.

SAFETY DEVICES

Over Heat Switches: When the heater gets too hot during operation (for example when air outlet louvres are
blocked) these devices turn the gas off automatically and allow the heater to restart when cooled down.
Electrical Fuse: The electrical circuits are protected by a fuse.
Flame Failure Sensing System: This device automatically cuts off the gas supply to the heater in the event of a
flame failure.
Power Failure: In the event of a power failure or power cut, the gas valves will automatically close.
Rinnai
SAFETY
9
SAPPHIRE RIB2312 OIM

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rib2312n

Table of Contents