ERROR CODES

In all cases, you may be able to clear the Error Message simply by turning the heater 'OFF', then
'ON' again. If the Error Message still remains or returns on the next operation, contact Rinnai or
WARNING
your nearest service agent and arrange for a service call.
Your Rinnai appliance is also fitted with self diagnostic electronics that monitor the appliance during start-up and
operation.
1
10
6
standard fascia shown for illustrative purposes
Should a fault occur the appliance will then shut down, the fault that has caused the shut down will be indicated by
a pair of flashing digits in the error display window cut outs
viewed by looking down through the upper edge of the return air vent
Refer to the table below for probable cause and the suggested remedy.
Code
Probable Cause
00
Mains power failure
11
Ignition failure
12
Incomplete combustion
14
Inlet Blockage / Overheat
16
Room overheat
31
Room temperature sensor faulty
32
Overheat temperature sensor faulty
33
Overheat temperature sensor faulty
53
Spark sensor faulty
61
Combustion fan motor faulty
71
Solenoids faulty
72
Flame detection circuit fault
73
Communication error
Rinnai
CARE AND MAINTENANCE
a
b
1
The error code viewing windows, are
on the top edge of the return air vent
and can only be viewed from above.
Interruption to the power or gas supply will turn your heater off and a
restart will be required. This is a safety feature designed to ensure
that un-attended starts do not occur after power or gas interruptions.
Access the 'Push Button Control Panel'
front of the heater at the lower right hand corner.
Press ON / OFF button
the ignition sparking and the heater will restart and return to normal
operation, after 30 seconds of operation the remote control may then
be used to select the desired flame height and fan speed.
Check gas supply is turned on, switch the heater to Standby and
then On again. If the error persists a service call will be required.
Check gas supply is turned on, switch the heater to Standby and
then On again. If the error persists contact Rinnai.
Clean inlets, if the error persists a service call will be required.
Lower room temp to below 40°C.
A service call will be required.
A service call will be required.
A service call will be required.
A service call will be required.
A service call will be required.
A service call will be required.
A service call will be required.
A service call will be required.
6
, which is located behind the fascia and can be
10
.
6
Suggested Remedy
twice, after which you will be able to hear
a
16
10
1
. This is located on the
SAPPHIRE RIB2312 OIM