Emerson Rosemount 5408 Reference Manual page 185

Level transmitters non-contacting radar
Hide thumbs Also See for Rosemount 5408:
Table of Contents

Advertisement

Table A-11:
Rosemount 5408:SIS Level Transmitter Ordering Information
Conduit electrical connector (shipped uninstalled)
EC
M 12, 4-pin, Male connector (eurofast)
MC
A size Mini, 4-pin, Male connector (minifast)
Specials (see
Section
A.3.2)
PXXXX
Custom Engineered Solutions beyond standard model codes. Consult factory for details.
Typical model number: 5408 F 1 S H A 1 E5 1 R 3 AB CAB 3 M5 DA1 EF2 QT
(1) The Rosemount 5408:SIS has two operational modes: Safety (SIS) and Control/Monitoring. Safety (SIS) mode must be set when used
in Safety Instrumented Systems. Control/Monitoring mode is intended for use in a Basic Process Control System (BPCS).
(2) Solids level measurement is only available when operating in Control/Monitoring mode.
(3) G½ thread form is not available with hazardous locations approvals.
(4) Type A flat face for EN 1092-1 flanges.
(5) Type B1 raised face for EN 1092-1 flanges.
(6) Pressure limit is derated for process temperatures above 100 °F (38 °C), see
(7) Refer to
Figure A-6
for pressure/temperature ratings of Tri-Clamp connection.
(8) Option code PC1 is for cone antennas only, and requires matching flange and antenna sizes. Note that all parabolic antennas come
with an integrated air purge connection.
(9) A minimum gasket thickness of 0.125 in. (3.2 mm) is required for flanges with protective plate design.
(10) The standard alarm setting is high.
(11) Only applies to flanged process connections with welded construction or protective plate design; only applicable to cone antennas (see
Table A-12
and
Table
A-13).
(12) Only available with ASME B16.5 flange connections, and materials of construction codes 1 and 7.
(13) Hydrostatic testing is only available for cone antennas and process seal antennas with flanged process connections.
(14) Certificate includes all pressure retaining and wetted parts.
(15) Only available for process seal antennas with Tri-Clamp connection.
(16) Not available with parabolic antenna.
(17) Requires ½-14 NPT conduit/cable threads (code 1). Available with Intrinsically Safe approvals only.
Rosemount 5408 and 5408:SIS Level Transmitters
(17)
Figure A-4
for details.
Specifications and Reference Data
(continued)
175

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rosemount 5408:sis

Table of Contents