7.4.4

Horn Speaker Test

Holding down [1] until two beeps sound activates the horn speaker for a 2-sec burst. No other
sounding device operates during this mode.
7.4.5

Bell Test

Holding down [2] until two beeps sound activates the internal screamers for a 2-sec burst. No
other sounding device operates during this mode.
7.4.6

Strobe Test

Holding down [3] operates the strobe. No other device operates during this mode.
To turn the strobe test on:
Press and hold [3] until three beeps sound. The strobe flashes.
To turn the strobe test off:
Press and hold [3] until two beeps sound. The strobe stops flashing.
7.4.7

Turning Day Alarm On and Off

Holding down [4] turns Day Alarm on or off. If you want the STAY indicator to indicate the
status of Day Alarm operation (enabled or disabled), select Option 8 in Location 496 (refer to
Consumer Options 1, page 141). When this option is selected, the STAY indicator flashes once
every 3 sec when Day Alarm is active.
To turn Day Alarm on:
Press and hold [4] until three beeps sound.
To turn Day Alarm off:
Press and hold [4] until two beeps sound.
7.4.8

Fault Analysis Mode

Several system faults can be detected by the control panel. When any of these faults are
present, the FAULT indicator flashes and the codepad beeps once per minute. Refer to Fault
descriptions, page 37 for more information.
To determine the type of fault:
Press and hold [5] until two beeps sound.
The STAY and AWAYindicators flash. One or more zone indicators (1 to 16) light to indicate the
type of fault that occurred.
To exit from Fault Analysis Mode:
Press [AWAY].
The STAY and AWAY indicators are extinguished and the system returns to the disarmed state.
7.4.9

Initiate a Modem Call

Holding down [6] until two beeps sound forces the control panel to dial the callback
telephone number programmed in Locations 159 to 174 in an attempt to connect to the
installer's remote computer.
The remote computer must be running the A-Link Software and must be set to Waiting for an
Incoming Call. If no callback telephone number is programmed, holding down [6] has no
effect.