en | System Reporting Information
15.7.17

AC Fail Report

An AC Fail Report (Contact ID Event Code 301) is sent to the base station receiver when the
AC MAINS supply is disconnected for 2 min. If you do not want an AC Fail Report to be sent
until the AC MAINS supply is disconnected for 1 hour, select Option 1 in Location 494.
15.7.18

AC Fail Restore Report

An AC Fail Restore Report is sent when the AC MAINS supply is connected continuously for
longer than 2 min.
15.7.19

Low Battery Report

A Battery Test Failure Report (Contact ID Event Code 302) is sent to the base station receiver
when the system's battery voltage falls below 11 VDC or when a Dynamic Battery Test detects
a low capacity battery.
The control panel continually monitors the battery voltage. A Dynamic Battery Test is done
every time the system is armed and every 4 hours after the control panel is powered up.
15.7.20

Low Battery Restore Report

A Low Battery Restore Report is sent if the backup battery is restored the next time the
system is armed, or when the next Dynamic Battery Test reports the battery test is OK when
the system's battery voltage rises to 12 VDC.