en | Communication Information
Format
CCC
S
Table 11.5: Contact ID Format Breakdown
11.22.2

SIA Format

SIA is a special format of using frequency shift keying (FSK) rather than a pulse to
communicate quickly.
SIA format is # AAAAAA N GGGGGG EE CCCCCC.
Format
#
AAAAAA
N
GGGGGG
EE
CCCCCC
Table 11.6: SIA Format Breakdown
11.22.3

System Reporting List

Index
Event Description
1
ZoneAlarm
2
ZoneAlarmRestore
3
ZoneTrouble
4
ZoneTroubleRestore
5
ZoneBypass
6
ZoneUnBypass
7
24HrZoneAlarm
8
24HrZoneAlarmRestore
9
24HrFireZoneAlarm
10
24HrFireZoneAlarmRestore
11
24HrMedicalZoneAlarm
12
24HrMedicalZoneAlarmRestor
e
13
24HrPanicZoneAlarm
2017.10 | 03 | F.01U.298.026
Description
Point ID Number or User Number (comprised of three hex digits), 000 means
no point or user information
Checksum digit
Description
Begin of Subscriber ID Number
Subscriber ID Number
Begin of event
Group / Area Number , User Number or Codepad Number
Event Code
Event Qualifier
CID
CID Point ID
Event
Code
1130
Zone 1 - 8 / 16
3130
Zone 1 - 8 / 16
1380
Zone 1 - 8 / 16
3380
Zone 1 - 8 / 16
1573
Zone 1 - 8 / 16
3573
Zone 1 - 8 / 16
1133
Zone 1 - 8 / 16
3133
Zone 1 - 8 / 16
1110
Zone 1 - 8 / 16
3110
Zone 1 - 8 / 16
1100
Zone 1 - 8 / 16
3100
Zone 1 - 8 / 16
1120
Zone 1 - 8 / 16
Installation Guide
SIA
String (Email / Codepad Display)
Event
Code
BA
Z$$ Alarm
BH
Z$$ Alarm Restore
BT
Z$$ Trouble
BJ
Z$$ Trouble Restore
BB
Z$$ Bypass
BU
Z$$ UnBypass
BA
24Hr Z$$ Alarm
BH
24Hr Z$$ Alarm Restore
FA
24Hr Fire Z$$ Alarm
FH
24Hr Fire Z$$ Alarm Restore
MA
24Hr Medical Z$$ Alarm
MH
24Hr Medical Z$$ Alarm Restore
PA
24Hr Panic Z$$ Alarm
Control Panel