Bosch Solution 2000 Installation Manual page 121

Hide thumbs Also See for Solution 2000:
Table of Contents

Advertisement

Control Panel
Item
Polarity
Time Base
Time Base Multiplier
Time Base Multiplier
For output item options, refer to below Output Item Options.
Item
B228 Output Mode
Event Code
Event Code
Bosch Security Systems, Inc.
Location Default
0744
0
0745
0
0746
0
0747
0
Option
0 = Not used
1 = Aux power
0 0 = Reserved
0 1 = System armed
0 2 = System disarmed
0 3 = Armed in STAY mode
0 4 = Armed in AWAY mode
0 5 = Pre-arming alert
0 6 = Exit Warning (all zones sealed) and
entry warning
0 7 = Exit Warning
0 8 = Exit Warning finished
0 9 = Kiss-off after end of Exit Time
0 10 = Reserved
0 11 = Entry warning
0 12 = Entry warning and day alarm resetting
0 13 = Exit warning and entry warning and
day alarm resetting
0 14 = Day alarm resetting
0 15 = Day alarm latching
2 0 = Strobe
2 1 = Silent alarm
2 2 = Alarm in STAY mode
2 3 = Alarm in AWAY mode
2 4 = System fault
2 5 = Fire alarm (resetting)
2 6 = Fire alarm (latching)
2 7 = Fire alarm (verification)
2 8 = Remote control 1
2 9 = Remote control 2
2 10 = Remote control 3
2 11 = Radio control output 1
2 12 = Radio control output 2
2 13 = Radio control output 1- not in AWAY
Mode
2 14 = Radio control output 2- not in AWAY
Mode
2 15 = Communications fail after 3 attempts
New
Item
Polarity
Time Base
Time Base Multiplier
Time Base Multiplier
Installation Guide
Programmable Outputs | en
Location Default
0750
0751
0752
0753
2 = Switched negative
4 = Open collector
1 0 = Day alarm enabled
1 1 = Telephone line fail
1 2 = Kiss-off received
1 3 = AUX Power Supply fail
1 4 = AC fail
1 5 = Low battery
1 6 = Output 1 fail
1 7 = Sensor watch alarm
1 8 = Codepad medical alarm
1 9 = Codepad fire alarm
1 10 = Codepad panic alarm
1 11 = Codepad duress alarm
1 12 = Access denied (code retries)
1 13 = Reserved
1 14 = Horn speaker (output 1 only)
1 15 = Siren running
3 0 = Communications fail
3 1 = Report disabled
3 2 = Report active (on-line)
3 3 = Ring detect
3 4 = Codepad/Keyfob panic
3 5 = Mimic zone 1
3 6 = Mimic zone 2
3 7 = Mimic zone 3
3 8 = Mimic zone 4
3 9 = Mimic zone 5
3 10 = Mimic zone 6
3 11 = Mimic zone 7
3 12 = Mimic zone 8
3 13 = Mimic zone 9
3 14 = Mimic zone 10
3 15 = Mimic zone 11
2017.10 | 03 | F.01U.298.026
121
New
0
0
0
0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Solution 3000

Table of Contents