External Network Modules - Bosch Solution 2000 Installation Manual

Hide thumbs Also See for Solution 2000:
Table of Contents

Advertisement

72
en | Communication Information
Item
Heart Beat Time – Receiver
2
ACK Wait Time – Receiver 3 1409 - 1410
Heart Beat Time – Receiver
3
ACK Wait Time – Receiver 4 1413 - 1414
Heart Beat Time – Receiver
4
These three Conettix items are only available when the Transmission Format is selected as
Conettix IP.
Conettix Anti-replay
This location has two programming options. You can select any combination of the options by
programming a single value. Calculate this value by adding the option bit numbers together.
Default is to enable Anti-replay for both receivers.
Conettix ACK Wait Time
ACK Wait Time set the time the control panel receives an acknowledgment from the receiver.
If the time is exceed and the acknowledgment is not yet received, the control panel assumes
the attempt is a failure and prepares for next attempt.
Conettix Heartbeat Time
Heartbeat time set the interval for network supervision. When the time is due, the control
panel transmits supervising signals to the receiver to ensure the network connect is normal.
With a text codepad, go to menu 717 Conettix ACK wait time, 718 Conettix heart beat time
and 719 Conettix anti-replay enable to set Conettix parameters for receivers.
11.7

External Network Modules

Item
External Network Module
1
External Network Module
2
Location 81 enables/disables the external network module 1.
Location 82 enables/disables the external network module 2.
If with text codepad, go to menu 721 Network Module to enable/disable the network module.
When the value of the location above is 0, the external network module is disabled
accordingly.
When the value is 1, the corresponding network module is enabled, but the control panel
won't configure parameters of network module.
When the value is 2, the corresponding network module is enabled, and the control panel will
configure the relevant parameters to network module.
When the value is 3, cloud module B4xx-M is selected, and Cloud Connection can be set
disabled or enabled.
2017.10 | 03 | F.01U.298.026
Location
Option
1407 - 1408
1 – 9 = 1 – 99 min.
0 – 9 = 0 – 99 sec.
1411 - 1412
1 – 9 = 1 – 99 min.
0 – 9 = 0 – 99 sec.
1415 - 1416
1 – 9 = 1 – 99 min.
Location
Option
0081
0 = Not used
1 = Use, do not configure
2 = Use and configure
0082
3 = Used, B4xx-M
Installation Guide
Control Panel
Default
New
1
5
1
5
1
Default
New
0
0
Bosch Security Systems, Inc.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Solution 3000