Arming The System In Stay Mode - Bosch Solution 2000 Installation Manual

Hide thumbs Also See for Solution 2000:
Table of Contents

Advertisement

32
en | System Operations
To disarm the system from AWAY Mode:
1.
2.
6.3

Arming the System in STAY Mode 1

STAY Mode 1 is used when you need to arm the perimeter and unused areas of the premises
to detect a would-be intruder entering the premises, while at the same time being able to
move freely within an area that is automatically isolated.
Only the installer can program zones to be automatically isolated in STAY Mode 1. Refer to
Zone Options 2, page 101 for more information on setting zones to be automatically isolated in
STAY Mode 1.
There are two methods to arm your system in STAY Mode 1. You can always use method one.
You can use method two only if Option 2 is enabled in Location 497 (refer to Consumer
Options 2, page 142).
If the system reports to a base station, it sends a STAY Mode 1 Arm Report (Contact ID Event
Code 441).
Entry Guard Time for STAY Mode
When arming the system in STAY Mode 1, an optional entry time called Entry Guard Time for
STAY Mode can be used to delay the sirens, strobe, and bell outputs if a zone that is not
automatically isolated activates an alarm. Entry Guard Time for STAY Mode is the delay time
used for all zones, except 24-Hour zones, when the system is armed in STAY Mode 1 or STAY
Mode 2. For more information, refer to Entry Guard Time for STAY Mode, page 135.
If the Entry Guard Time for STAY Mode is programmed and a zone that was not automatically
isolated is activated, the codepad beeps twice per sec until the Entry Guard Time for STAY
Mode expires or the system is disarmed. If the alarm is not reset before Entry Guard Time for
STAY Mode expires, the strobe, bell, and siren outputs are activated into alarm.
Notice!
Single button arming in STAY Mode 1 reports as User Code number 00.
To arm the system in STAY Mode 1 (method one):
1.
2.
The indicators for any zones that are programmed to be automatically isolated in STAY Mode 1
begin to flash until Exit Time expires. At the end of Exit Time, the zone indicators are
extinguished and the codepad sounds one short beep.
To arm the system in STAY Mode 1 (method two):
1.
2.
The indicators for any zones that are programmed to be automatically isolated in STAY Mode 1
flash until Exit Time expires. At the end of Exit Time, the zone indicators are extinguished and
the codepad sounds one short beep.
If a zone is not sealed at the end of Exit Time, the zone is automatically isolated and is lit
constantly on the remote codepad. The zone becomes an active part of the system again as
soon as it is resealed. For example, if a window is open when Exit Time expires, the window
does not become an active part of the system until it is closed. Opening the window after Exit
Time expires causes an alarm.
Forced Arming
2017.10 | 03 | F.01U.298.026
Enter your code and press [AWAY].
Two beeps sound and the AWAY indicator is extinguished.
Enter your code and press [STAY].
Two beeps sound and the STAY indicator is lit. Exit Time starts.
Press and hold [STAY].
When two beeps sound, release the button. The STAY indicator is lit and Exit Time starts.