Communication Setting Using Parameter Method (Gx Works2) - Mitsubishi Electric FX3U-232-BD User Manual

Melsec-f fx series programmable controllers data communication edition
Table of Contents

Advertisement

FX Series PLC User's Manual - Data Communication Edition
Common Items
3.2

Communication Setting Using Parameter Method (GX Works2)

Communication settings may be changed by the parameter method with GX Works2, GX Developer,
FXGP/WIN for Windows and FX-30P handy programming panel. This section describes how to change
parameters with GX Works2.
For details on GX Developer operating procedure, refer to GX Developer Operating Manual.
3.2.1
Operating procedure
With GX Works2 open, follow the steps in this section for activating the serial communication setting method.
1
Opening the parameter setting window
In the project view area of the navigation window, double-click [Parameter]  [PLC Parameter].
If the navigation window is not displayed, select [View]  [Docking Window]  [Navigation] from
the menu bar.
2
Setting the serial communication (parameters)
Click the [PLC System(2)] tab on the dialog box.
When using programming communication, parallel link, N:N Network or remote maintenance, do
not check the "Operate Communication Setting" box.
When using computer link, inverter communication or non-protocol communication (RS/RS2
instruction) function, check the "Operate Communication Setting" box, and then set each item.
Click [End].
3
Writing parameters to the PLC
Select [Online]  [Write to PLC] from the menu bar, click [Parameter + Program], and then click
[Execute].
For details on FXGP/WIN operating procedure, refer to section 3.3.
For details on FX-30P operating procedure, refer to FX-30P Operation Manual.
3 Outline of Communication Setting in the FX Series
3.2 Communication Setting Using Parameter Method (GX Works2)
A
B
C
D
E
F
G
H
I
Apx.A
A-67