Link Specifications

The tables below show applicable parameters and operation commands.
When monitoring inverter operations (PLC  inverter)
2.3.1
Instruction code
(hexadecimal)
H7B
Operation mode
H6F
Output frequency [number of rotations]
H70
Output current
H71
Output voltage
H72
Special monitor
H73
Special monitor selection number
H74
Alarm definition
H75
Alarm definition
H76
Alarm definition
H77
Alarm definition
H79
Inverter status monitor (extended)
H7A
Inverter status monitor
H6E
Set frequency (EEPROM)
H6D
Set frequency (RAM)
H7F
Link parameter expansion setting
H6C
Second parameter changing
When controlling inverter operations (PLC  inverter)
2.3.2
Instruction code
(hexadecimal)
HFB
HF3
HF9
HFA
HEE
HED
HFD
HF4
HFC
HFC
HFF
Parameters (PLC  inverter)
2.3.3
For inverter parameters which can be changed (read and written), refer to "12. Related Detailed Data" later.
Read contents
Written contents
Operation mode
Special monitor selection number
Run command (expansion)
Run command
Set frequency (EEPROM)
Set frequency (RAM)
Inverter reset
Alarm definition all clear
All parameter all clear
User clear
Link parameter expansion setting
Applicable inverter
F800, A800, F700,
V500, F500, A500
A700, E700, D700
Refer to Subsection 9.4.2
Applicable inverter
F800, A800, F700,
V500
A700, E700, D700
2 Specifications
2.3 Link Specifications
E500
S500
F500, A500
E500, S500
E-9
A
B
C
D
E
F
G
H
I
Apx.A