Inverter Communication

12.5.3 Parameters in F800 and A800 Series

The following parameters are provided in FREQROL inverters. Pr. No.1000 and later are not supported.
(For details, make sure to refer to the respective inverter manual.)
Pr
Function
No.
0
1
2
3
4
Basic functions
5
6
7
8
9
10
DC injection
brake
11
12
13
14
15
Jog operation
16
17
18
-
19
20
Acceleration/
deceleration
times
21
22
Stall prevention
23
24
25
Multi-speed
setting
26
27
28
29
30
31
32
33
Frequency jump
34
35
36
E-190
FREQROL F800 Series
Pr
Name
Group
G000
Torque boost
H400
Maximum frequency
H401
Minimum frequency
G001
Base frequency
D301
Multi-speed setting (high speed)
D302
Multi-speed setting (middle speed)
D303
Multi-speed setting (low speed)
F010
Acceleration time
F011
Deceleration time
H000
Electronic thermal O/L relay
C103
Rated motor current
DC injection brake operation
G100
frequency
G101
DC injection brake operation time
G110
DC injection brake operation voltage
F102
Starting frequency
G003
Load pattern selection
D200
Jog frequency
F002
Jog acceleration/deceleration time
T720
MRS input selection
H402
High speed maximum frequency
G002
Base frequency voltage
Acceleration/deceleration reference
F000
frequency
Acceleration/deceleration time
F001
increments
H500
Stall prevention operation level
Stall prevention operation level
H610
compensation factor at double
speed
D304
Multi-speed setting (4 speed)
D305
Multi-speed setting (5 speed)
D306
Multi-speed setting (6 speed)
D307
Multi-speed setting (7 speed)
Multi-speed input compensation
D300
selection
Acceleration/deceleration pattern
F100
selection
E300
Regenerative function selection
H420
Frequency jump 1A
H421
Frequency jump 1B
H422
Frequency jump 2A
H423
Frequency jump 2B
H424
Frequency jump 3A
H425
Frequency jump 3B
12.5 FREQROL Inverter Parameter List
FREQROL A800 Series
Pr
Pr
No.
Group
0
G000
Torque boost
1
H400
Maximum frequency
2
H401
Minimum frequency
3
G001
Base frequency
4
D301
Multi-speed setting (high speed)
5
D302
Multi-speed setting (middle speed)
6
D303
Multi-speed setting (low speed)
7
F010
Acceleration time
8
F011
Deceleration time
H000
Electronic thermal O/L relay
9
C103
Rated motor current
DC injection brake operation
10
G100
frequency
11
G101
DC injection brake operation time
12
G110
DC injection brake operation voltage
13
F102
Starting frequency
14
G003
Load pattern selection
15
D200
Jog frequency
16
F002
Jog acceleration/deceleration time
17
T720
MRS input selection
18
H402
High speed maximum frequency
19
G002
Base frequency voltage
Acceleration/deceleration reference
20
F000
frequency
Acceleration/deceleration time
21
F001
increments
Stall prevention operation level
22
H500
(Torque limit level)
Stall prevention operation level
23
H610
compensation factor at double
speed
24
D304
Multi-speed setting (4 speed)
25
D305
Multi-speed setting (5 speed)
26
D306
Multi-speed setting (6 speed)
27
D307
Multi-speed setting (7 speed)
Multi-speed input compensation
28
D300
selection
Acceleration/deceleration pattern
29
F100
selection
30
E300
Regenerative function selection
31
H420
Frequency jump 1A
32
H421
Frequency jump 1B
33
H422
Frequency jump 2A
34
H423
Frequency jump 2B
35
H424
Frequency jump 3A
36
H425
Frequency jump 3B