Specifications of I/O Data

This section describes I/O data for the Digital Mixed I/O Units.
8-2-1

Allocable I/O Data

This section describes the allocable I/O data in the Digital Mixed I/O Units.
An I/O entry mapping is assigned to the I/O allocation settings for the Digital Mixed I/O Units.
A specific I/O entry is assigned to the I/O entry mapping for each NX Unit model. These allocations are
fixed, so you cannot add others or change them.
An I/O entry means the I/O data described in this section. An I/O entry mapping means a collection of
I/O entries.
To assign the I/O allocation information of the EtherCAT Slave Terminal to an NJ-series CPU Unit, use
the I/O ports for the allocated I/O data.
NX Units in Free-Run Refreshing or Synchronous I/O Refreshing
 Thirty-two-point Mixed I/O Units
Input section
Data name
Input Bit 16 bits
Input Bit 00
Input Bit 01
Input Bit 15
NX-series Digital I/O Unit User's Manual (W521)
Data
Description
type
The input values for 16
WORD
bits.
The following 16 BOOL
data are included.
The input value for input
BOOL
bit 00.
The input value for input
BOOL
bit 01.
The input value for input
BOOL
bit 15.
8 Digital Mixed I/O Units
Default
I/O port
value
name
0000 hex
Input Bit 16
bits
FALSE
Input Bit 00
FALSE
Input Bit 01
FALSE
Input Bit 15
Subin-
Index
dex
6002 hex
01 hex
8
8 - 3