Omron NX-ID3343 User Manual page 323

Nx-series digital i/o units machine automation controller
Table of Contents

Advertisement

Index
Subindex
(hex)
(hex)
7003
DWORD Output
00
Number of Entries
01
Output Bit 32 bits
*1. The default value and data range for Number of Entries are as follows.
NX Units
NX-OD6121-5/OD6256-5
Other models
*2. Detailed data for Output Bit 32 bits are as follows.
Bit 0: Output Bit 00
Bit 1: Output Bit 01
·
·
·
Bit 31: Output Bit 31
Index
Subindex
(hex)
(hex)
7010
Time Stamp
00
Number of Entries
01
Output Bit 00 Time Stamp
02
Output Bit 01 Time Stamp
*1. The default value and data range for Number of Entries are as follows.
NX Units
NX-OD2154/OD2258
Other models
NX-series Digital I/O Unit User's Manual (W521)
Default
Object name
value
*1
00000000
hex
Default value
1
0
Default
Object name
value
*1
0
Default value
2
0
Data
Data range
Unit
type
USINT
*1
00000000 to
DWORD
FFFFFFFF
*2
hex
Data range
1 (fixed)
0 (fixed)
Data
Data range
Unit
type
*1
USINT
0 to
ns
ULINT
+18446744073
709551615
ULINT
Data range
2 (fixed)
0 (fixed)
Appendices
I/O
Data
Acc
allo-
attri-
ess
cat-
bute
ion
RO
Not
possi
ble
RW
Possi
N
ble
A
I/O
Data
Acc
allo-
attri-
ess
cat-
bute
ion
RO
Not
pos-
sible
RW
Pos-
N
sible
RW
Pos-
N
sible
A - 93

Hide quick links: