21.5 Setting the eccentric on the upper shaft
Proper setting
In the 1
upper edge of the throat plate), the 1
the blade drive eccentric should line up with the pull rod.
Fig. 114: Setting the eccentric on the upper shaft
(1) - Blade drive eccentric
(2) - Pull rod
Cover
• Remove the arm cover ( p. 20).
To set the eccentric on the upper shaft:
1. Loosen the screws on the blade drive eccentric (1).
2. Turn the handwheel until the machine is in the 1
3. Adjust the blade drive eccentric (1) such that the 1
4. Tighten the screws on the blade drive eccentric (1) again.
112
WARNING
Risk of injury!
Crushing, cutting and punctures are possible.
Only set the eccentric on the upper shaft with the
machine switched off.
st
needle position (lower edge of the needle eye level with the
①
with the pull rod (2).
st
screw in the rotational direction of
②
③
(3) - Screw
Service Instructions 195 - 00.0 - 12/2017
Edge cutter
st
needle position.
st
screw lines up