Alcatel-Lucent 7450 ESS-12 Configuration Manual page 433

Os basic system 7450 ess series ethernet service switch
Table of Contents

Advertisement

Default
300
Parameters
interval — Specifies the boot timer interval.
Values
hold-on-neighbor-failure
Syntax
hold-on-neighbor-failure multiplier
no hold-on-neighbor-failure
Context
config>redundancy>multi-chassis>peer>mc-ep
Description
This command specifies the number of keep-alive intervals that the local node will wait for packets from the
MC-EP peer before assuming failure. After this time interval passed the all the mc-endpoints configured
under services will revert to single chassis behavior, activating the best local pseudowire.
The no form of this command sets the multiplier to default value
Default
3
Parameters
multiplier — Specifies the hold time applied on neighbor failure.
Values
keep-alive-interval
Syntax
keep-alive-interval interval
no keep-alive-interval
Context
config>redundancy>multi-chassis>peer>mc-ep
Description
This command sets the interval at which keep-alive messages are exchanged between two systems
participating in MC-EP when bfd is not enabled or is down. These fast keep-alive messages are used to
determine remote-node failure and the interval is set in deci-seconds.
The no form of this command sets the interval to default value
Default
5 (0.5s)
Parameters
interval — The time interval expressed in deci-seconds.
Values
Page 404
1 — 600
2 — 25
5 — 500 (tenths of a second)
7450 ESS OS Basic System Configuration Guide