this threshold, a single threshold crossing event will be generated. A single threshold crossing event
will also be generated if the first sample taken is less than or equal to this threshold and the associated
'startup-alarm' is equal to 'falling' or 'either'.
After a falling threshold crossing event is generated, another such event will not be generated until the
sampled value rises above this threshold and reaches greater than or equal the rising-threshold value.
Default
Values
owner owner — The owner identifies the creator of this alarm. It defaults to "TiMOS CLI". This
parameter is defined primarily to allow entries that have been created in the RMON-MIB alarmTable by
remote SNMP managers to be saved and reloaded in a CLI configuration file. The owner will not
normally be configured by CLI users and can be a maximum of 80 characters long.
Default
Configuration example:
alarm 3 variable-oid ifInOctets.184582144 interval 20 sample-type delta start-alarm either
rising-event 5 rising-threshold 10000 falling-event 5 falling-threshold 9000 owner "TiMOS
CLI"
cflash-cap-alarm
Syntax
cflash-cap-alarm cflash-id rising-threshold threshold [falling-threshold threshold] interval
seconds [rmon-event-type] [startup-alarm alarm-type]
no cflash-cap-alarm cflash-id
Context
config>system>thresholds
Description
This command enables capacity monitoring of the compact flash specified in this command. The severity
level is alarm. Both a rising and falling threshold can be specified.
The no form of this command removes the configured compact flash threshold alarm.
Parameters
cflash-id — The cflash-id specifies the name of the cflash device to be monitored.
Values
rising-threshold threshold — Specifies a threshold for the sampled statistic. When the current sampled
value is greater than or equal to this threshold, and the value at the last sampling interval was less than
this threshold, a single threshold crossing event will be generated. A single threshold crossing event
will also be generated if the first sample taken is greater than or equal to this threshold and the
associated 'startup-alarm' is equal to 'rising' or 'either'.
After a rising threshold crossing event is generated, another such event will not be generated until the
sampled value falls below this threshold and reaches less than or equal the 'falling-threshold' value.
Default
Values
falling-threshold threshold — Specifies a threshold for the sampled statistic. When the current sampled
value is less than or equal to this threshold, and the value at the last sampling interval was greater than
Page 332
0
-2147483648 — 2147483647
TiMOS CLI
cf1:, cf1-A:,cf1-B:,cf2:,cf2-A:,cf2-B:,cf3:,cf3-A:,cf3-B:
0
-2147483648 — 2147483647
7450 ESS OS Basic System Configuration Guide