Configuring Manual Synchronization

Note that automatic synchronization can be configured in the config>system> synchronization
context.
CLI Syntax: admin
Example
The following shows the output which displays during a manual synchronization:
A:ALA-12>admin# synchronize config
Syncing configuration......
Syncing configuration.....Completed.
A:ALA-12#

Forcing a Switchover

The force-switchover now command forces an immediate switchover to the standby CPM card.
CLI Syntax: admin>redundancy
Example
A:ALA-12# admin redundancy force-switchover now
A:ALA-12#
Resetting...
?
If the active and standby are not synchronized for some reason, users can manually synchronize
the standby CPM by rebooting the standby by issuing the admin reboot standby command on
the active or the standby CPM.
7450 ESS OS Basic System Configuration Guide
redundancy
synchronize {boot-env|config}
:
admin>redundancy# synchronize config
force-switchover [now]
:
admin>redundancy# force-switchover now