Configuring Power Supply Parameters

By default, 7450 ESS-Series
-----------------------------------------------------------------
..
..
-----------------------------------------------------------------
A:ALA-12>config>system#
7450 ESS OS Basic System Configuration Guide
A:ALA-12>config>system# info
name "ALA-12"
contact "Fred Information Technology"
location "Bldg.1-floor 2-Room 201"
clli-code "abcdefg1234"
coordinates "N 45 58 23, W 34 56 12"
power-supply 1 dc
power-supply 2 dc
lacp-system-priority 1
sync-if-timing
begin
ref-order ref1 ref2 bits
ref1
shutdown
exit
ref2
shutdown
exit
bits
shutdown
interface-type ds1 esf
exit
commit
exit