Overview

The Reactor E-10 is a portable, electric-pow-
ered, 4:1 mix ratio proportioner, for use with a
wide variety of coatings, foams, sealants, and
adhesives. Materials must be self-leveling and
pourable, and may be applied with impinge-
ment mix spray guns, disposable mixer guns,
or flush-type mix manifolds.
Reactor E-10 is siphon-fed from 5 gallon pails
that can be mounted on the unit.
Severe duty, positive displacement reciprocat-
ing piston pumps meter fluid flow to the gun for
mixing and applying. When set to recirculation
mode, Reactor E-10 will circulate fluids back to
the 5 gallon pails.
The Reactor E-10 includes separate thermo-
statically controlled heaters for each fluid. Digi-
tal displays show the temperatures of the two
fluids.
An electronic processor controls the motor,
monitors fluid pressures, and alerts the opera-
tor if errors occur. See STATUS Indicator,
page 10, for further information.
An air compressor provides and regulates air
pressure for the spray gun.
8
Reactor E-10 has two recirculation speeds,
slow and fast, and an adjustable pressure out-
put.
Slow Recirculation
Slow circulation results in a higher temper-
ature transfer in the heater, so hoses and
gun heat up quicker.
Good for touchup or low flow spraying, up
to moderate temperature.
Not used to circulate full tanks up to tem-
perature.
Fast Recirculation
Use to support higher flow rates or higher
temperatures by preheating the tanks.
Agitates fluid within tanks, to avoid heating
only the fluid at the top of the tank.
Use for flushing.
Pressure Adjust
Automatically maintains selected pressure out-
put for dispensing or spraying.
Keep Components A
and B Separate
CAUTION
To prevent cross-contamination of the equip-
ment's wetted parts, never interchange com-
ponent A (white fluid) and component B (red
fluid) parts.