Overview

Overview
Overview
Overview
The purpose of the XP PressureTrak is to shut down
the sprayer if abnormal pressure conditions are
detected in order to prevent spraying material that is
not mixed on ratio.
Two pressure transducers read the A and B fluid
pressures in the outlet manifold and send the
readings back to the XP PressureTrak.
The XP PressureTrak monitors the difference
between the A and B fluid pressures, alerting the
user when an imbalance is detected. An imbalance
may be due to a plug, leak, or running out of fluid.
When an imbalance is detected, the electric solenoid
disables the air motor, an alarm is displayed on
the screen, and the LED on the front of the display
flashes. For more error code information see
Alarms, Deviations, and Advisories, page
The following alarms can occur:
• Differential Pressure (B>A)
• Differential Pressure (A>B)
• Pressure A High
• Pressure B High
• Electric Solenoid Disconnected
• Pressure A Disconnected
• Pressure B Disconnected
• Low Battery
• Blown Fuse
4

Operating Window

Operating
Operating
Below Minimum
Below
Below
Minimum Spray
Minimum
The air motor is allowed to automatically operate in
Circulation Mode any time the fluid pressures are
below the minimum spray pressure. This allows for
loading the system and circulating the fluids without
alarms or shutdowns.
Above Minimum
Minimum Spray
Above
Above
Minimum
When the XP PressureTrak detects the fluid
pressures above the minimum spray pressure for
30 seconds, and the pressures are balanced within
the pre-set limits, it will automatically start pressure
monitoring. If the XP PressureTrak does not see
balanced pressures within 30 seconds of going
above the minimum spray pressure, it will detect the
fault and disable the air motor. The default minimum
spray pressure is 2000 psi (14 MPa, 138 bar). Enter
14.
Setup Mode to change the minimum spray pressure
as necessary (see
Maximum Spray
Maximum
Maximum
The XP PressureTrak will alarm and shutdown if
it detects either A or B fluid pressures above the
maximum working pressure (see table below). Enter
Setup Mode to reduce the maximum allowable
pressure set point (see
Model
Model
Model
17C807
17C808
17N936
Window
Window
Spray Pressure
Spray
Pressure
Pressure
Spray Pressure
Pressure
Spray
Pressure
Setup Mode Details, page
Spray Pressure
Pressure
Spray
Pressure
Setup Mode Details, page
Maximum Working
Working Pressure
Maximum
Maximum
Working
7250 psi (500 Bar, 50 MPa)
7500 psi (520 Bar, 52 MPa)
22).
22).
Pressure
Pressure
3A3320D