Drive Housing - Graco Reactor E-10 Instructions-Parts List Manual

For spraying or dispensing 4:1 mix ratio materials, including epoxies, polyurethane foam, and polyurea coatings. not for use in explosive atmospheres
Hide thumbs Also See for Reactor E-10:
Table of Contents

Advertisement

Drive Housing

Removal
1. See Before Beginning Repair, page 35.
Relieve pressure, page 22.
2. Remove screws (207) and end covers (221,
227), F
. 14.
IG
Examine connecting rod (216). If rod
needs replacing, first remove the pump
(219), page 37.
CAUTION
Do not drop gear reducer (214) and crank-
shaft (210) when removing drive housing
(215). These parts may stay engaged in
motor end bell (MB) or may pull away with
drive housing.
3. Disconnect pump inlet and outlet lines.
Remove screws (220) and pull drive hous-
ing (215) off motor (201) Connecting rod
(216) will disengage from crankshaft (210).
4. Examine crankshaft (210), gear reducer
(214), thrust washers (208, 212), and bear-
ings (209, 211, 213).
Installation
1. Apply grease liberally to washers (208,
212), bearings (209, 211, 213), gear
reducer (214), crankshaft (210), and inside
drive housing (215). Grease is supplied
with replacement parts kits.
313221A
B side crankshaft (210) includes the
cycle counter magnet (224). When
reassembling, be sure to install crank-
shaft with magnet on B side.
If replacing crankshaft, remove magnet
(224). Reinstall magnet in center of off-
set shaft on new crankshaft. Position
shaft in Park position.
2. Install bronze bearings (211, 213) in drive
housing (215), as shown.
3. Install bronze bearings (209, 211) and steel
washer (208) on crankshaft (210). Install
bronze bearing (213) and steel washer
(212) on gear reducer (214).
4. Install gear reducer (214) and crankshaft
(210) into motor end bell (MB).
Crankshaft (210) must be in line with
crankshaft at other end of motor. Pumps
will move up and down together.
If connecting rod (216) or pump (219)
were removed, reassemble rod in hous-
ing and install pump, page 37.
5. Push drive housing (215) onto motor (201).
Install screws (220).
6. Install drive housing covers (221 on A side,
227 on B side) and screws (207). Pumps
must be in phase (both at same position in
stroke).
Repair
45

Advertisement

Table of Contents
loading