Repair; Before Beginning Repair - Graco Reactor E-10 Instructions-Parts List Manual

For spraying or dispensing 4:1 mix ratio materials, including epoxies, polyurethane foam, and polyurea coatings. not for use in explosive atmospheres
Hide thumbs Also See for Reactor E-10:
Table of Contents

Advertisement

Repair

Before Beginning Repair

Repairing this equipment requires access to
parts which may cause electric shock or
other serious injury if work is not performed
properly. Have a qualified electrician connect
power and ground to main power switch ter-
minals, see page 13. Be sure to shut off all
power to the equipment before repairing.
1. Flush if possible, see page 24. If not possi-
ble, clean all parts with solvent immediately
after removal.
2. Set function knob to Stop/Park
3. Shut off Motor Power. Disconnect power
supply.
4. Shut off Heater Power. Allow equipment to
cool before repairing.
5. Relieve pressure, page 22.