Graco Reactor E-10 Instructions-Parts List Manual page 15

For spraying or dispensing 4:1 mix ratio materials, including epoxies, polyurethane foam, and polyurea coatings. not for use in explosive atmospheres
Hide thumbs Also See for Reactor E-10:
Table of Contents

Advertisement

4.
Connect fluid hoses
Connect fluid supply hoses to outlet
hose connections (R, F
are sized to prevent connection errors.
Connect other end of hoses to A and B
inputs of gun.
5.
Connect gun air hose
Connect gun air hose to the gun air
input and to the air filter outlet (Z). If you
are using more than one hose bundle,
join the air hoses with the nipple (305)
provided with the hose bundle.
On heated units with Fusion guns, con-
nect the supplied ball valve and
quick-disconnect coupler to the gun air
hose, then connect the coupler to the
gun air fitting.
F
. 6. Hose Connections
IG
313221A
. 6). Fittings
IG
R
Z
6.
Turn on air compressor
Turn on air compressor power. Set regu-
lator to desired output pressure as indi-
cated on the gauge.
Air Filter/Moisture Separator (Z) is
equipped with an automatic moisture
drain.
7.
Flush before first use
The Reactor E-10 is tested with a plasti-
cizer oil at the factory. Flush out the oil
with a compatible solvent before spray-
ing. See page 24.
Setup
15

Advertisement

Table of Contents
loading