8.
Fill wet-cups
Keep the felt washers in the pump
wet-cups saturated with Owens Corning
plasticizer; see Owens Corning Distribu-
tor. The lubricant creates a barrier
between the red fluid and the atmo-
sphere.
Pump rod and connecting rod move during
operation. Moving parts can cause serious
injury such as pinching or amputation. Keep
hands and fingers away from wet-cup dur-
ing operation. Shut off Motor Power
before filling wet-cup.
Fill wet-cups through slots
in plate, or loosen screws
and swing plate aside.
9.
Install suction tube
CAUTION
To prevent cross-contamination of fluids and
equipment parts, never interchange compo-
nent A and component B parts or containers.
Label one pail "A" and the other "B", using
the labels provided. Always doublecheck
which material you have before placing suc-
tion tubes in pails.
16
Using a drill and mixing blade, mix filled or
separated materials in the pail. Material
left in the tanks overnight may need to be
remixed.
a.
b.
A
TI6985a
c.
Open red and white fluid pails
and position in front of suction
tubes.
Stand behind unit and hold cross-
bar. Lean unit backwards until the
suction tubes are above the sup-
ply pails.
B
Place suction tubes in pails.
A
B