Graco Reactor E-10 Instructions-Parts List Manual page 31

For spraying or dispensing 4:1 mix ratio materials, including epoxies, polyurethane foam, and polyurea coatings. not for use in explosive atmospheres
Hide thumbs Also See for Reactor E-10:
Table of Contents

Advertisement

PROBLEM
B side rich; lack of A side.
No temperature display.
Wrong temperature displayed.
Temperature displays do not
match at ambient temperature.
313221A
CAUSE
A side gauge is low.
B side gauge is low.
Loose display cables on control
board.
Failed control board (displays get
power from control board).
Inadequate power to control
board.
Loose power cable.
Motor Power switch circuit
breaker tripped.
°F/°C switch in wrong position.
Displays need calibration.
Troubleshooting
SOLUTION
A side material supply problem.
Check A side inlet strainer and
pump intake valve.
A side restriction downstream of
gauge. Check gun check valve
screen, mix module, or mix mani-
fold restrictor.
Check cable connections to each
display, page 42.
Remove access panel. Check if
board LED is lighted. If not,
replace board, page 42.
Check that power supply meets
requirements.
Check cable connections, page
42.
Display is powered from Motor
Power circuit breaker. Cycle Motor
Power off
, then on
to reset breaker.
Set switch, see page 39.
Turn calibration screw on back of
displays to correct reading, see
page 39.