Graco Reactor E-10 Instructions-Parts List Manual page 33

For spraying or dispensing 4:1 mix ratio materials, including epoxies, polyurethane foam, and polyurea coatings. not for use in explosive atmospheres
Hide thumbs Also See for Reactor E-10:
Table of Contents

Advertisement

PROBLEM
Air compressor does not run
313221A
CAUSE
Power is not on.
Voltage to compressor below 105
Vac for 120 Vac.
Loose power connections.
Excessive head pressure (com-
pressor hums)
Compressor thermal switch is
open. Ensure ambient tempera-
ture is below 115°F (46°C).
Low compressor performance
Troubleshooting
SOLUTION
Turn compressor power on.
Try another outlet. Reduce exten-
sion cord length or increase
extension cord gauge.
Verify all connections are firm.
Moisture frozen in air supply line.
Wait for air pressure to bleed to
zero.
Electrical air unloader stuck
closed. Replace electrical air
unloader.
Open air regulator; install air line.
Complete Setup on page 13.
Move sprayer to shaded, cooler
area.
Worn compressor; replace com-
pressor with Compressor Service
Kit 256779.