Chrysler 2000 LHS Owner's Manual page 1556

Table of Contents

Advertisement

LH
DESCRIPTION AND OPERATION (Continued)
(M) Check Engine Lamp (MIL) will illuminate during engine operation if this Diagnostic Trouble Code was
recorded.
(G) Generator Lamp Illuminated
GENERIC
DRB SCAN TOOL DISPLAY
SCAN TOOL
CODE
P0122 (M)
Throttle Position Sensor Voltage Low
P0123 (M)
Throttle Position Sensor Voltage
P0125 (M)
Closed Loop Temp Not Reached
P0130
1/1 O2 Sensor Heater Relay Circuit
P0131 (M)
1/1 O2 Sensor Shorted To Ground
P0132 (M)
1/1 O2 Sensor Shorted To Voltage
P0133 (M)
1/1 O2 Sensor Slow Response
P0134 (M)
1/1 O2 Sensor Stays at Center
P0135 (M)
1/1 O2 Sensor Heater Failure
P0136
1/2 O2 Sensor Heater Relay Circuit
P0137 (M)
1/2 O2 Sensor Shorted To Ground
P0138 (M)
1/2 O2 Sensor Shorted To Voltage
P0139 (M)
1/2 O2 Sensor Slow Response
P0140 (M)
1/2 O2 Sensor Stays at Center
P0141 (M)
1/2 O2 Sensor Heater Failure
P0143
1/3 O2 Sensor Shorted To Ground
P0144
1/3 O2 Sensor Shorted To Voltage
P0145
1/3 O2 Sensor Slow Response
P0146
1/3 O2 Sensor Stays at Center
P0147
1/3 O2 Sensor Heater Failure
P0151 (M)
2/1 O2 Sensor Shorted To Ground
P0152 (M)
2/1 O2 Sensor Shorted To Voltage
P0153 (M)
2/1 O2 Sensor Slow Response
High
EMISSION CONTROL SYSTEMS
DESCRIPTION OF DIAGNOSTIC TROUBLE CODE
Throttle position sensor input below the acceptable
voltage range.
Throttle position sensor input above the maximum
acceptable voltage.
Time to enter Closed Loop Operation (Fuel Control) is
An open or shorted condition detected in the ASD or CNG
shutoff relay control ckt.
Oxygen sensor input voltage maintained below normal
operating range.
Oxygen sensor input voltage maintained above normal
operating range.
Oxygen sensor response slower than minimum required
switching frequency.
Neither rich or lean condition is detected from the oxygen
sensor input.
Oxygen sensor heater element malfunction.
An open or shorted condition detected in the ASD or CNG
shutoff relay control ckt.
Oxygen sensor input voltage maintained below normal
operating range.
Oxygen sensor input voltage maintained above normal
operating range.
Oxygen sensor response not as expected.
Neither rich or lean condition is detected from the oxygen
Oxygen sensor heater element malfunction.
Oxygen sensor input voltage maintained below normal
operating range.
Oxygen sensor input voltage maintained above normal
operating range.
Oxygen sensor response slower than minimum required
switching frequency.
Neither rich or lean condition is detected from the oxygen
Oxygen sensor heater element malfunction.
Oxygen sensor input voltage maintained below normal
operating range.
Oxygen sensor input voltage sustained above normal
operating range.
Oxygen sensor response slower than minimum required
switching frequency.
excessive.
sensor.
sensor.
25 - 3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

300mConcordeIntrepid

Table of Contents