SiENBE04-925_A
4.7

Removal of Thermistors

Procedure
Step
1
Release the discharge
pipe thermistor.
2
Cut the clamp and pull
out the outdoor heat
exchanger thermistor.
3
The thermistors for
outdoor temperature /
discharge pipe /
outdoor heat exchanger
are united as one
assembly.
4
The figure shows the
arrangement of the
thermistors.
Removal Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Discharge pipe thermistor
Outdoor Unit - RXL25G2V1B
„ Be careful not to lose the clip
for the thermistor.
(R8192)
Outdoor heat
exchanger thermistor
(R8193)
(R8194)
Points
Clip
(R12279)