Indoor Unit
Step
2. Remove the swing motor
for horizontal blade.
1
Remove the screw and
remove the swing
motors for horizontal
blades.
2
Disconnect the
harnesses from the
motors.
152
Procedure
Connector for
lower blade (red)
Screw
Connector for
upper blade (white)
Points
Caution
When reassembling, do not
confuse the installing order
of the 2 motors and the
colors of the connectors.
If you set the connectors or
motors opposite, the
horizontal blades do not
move smoothly or the noise
may be heard.
(1) Set the motor for the upper
blade first.
(connector: white)
(2) Then, set the motor for the
(R8131)
lower blade.
(connector: red)
(3) Fix the both motors with a
screw.
(R8132)