Control Specification
3.3.2 Four Way Valve Switching
Outline
In heating operation, current is conducted, and in cooling and defrosting, current is not
conducted. In order to eliminate the switching sound when the heating is stopped, as the four
way valve coil switches from ON to OFF, the OFF delay switch of the four way valve is carried
out after the operation stopped.
Detail
OFF delay switch of four way valve:
The four way valve coil is energized for 150 ~ 160 seconds after the operation is stopped.
3.3.3 Four Way Valve Operation Compensation
Outline
At the beginning of the operation as the four way valve is switched, the differential pressure to
activate the four way valve is acquired by having output frequency which is more than a certain
fixed frequency, for a certain fixed time.
Detail
Starting Conditions
1. When starting compressor for heating.
2. When the operation mode changes to cooling from heating.
3. When starting compressor for defrosting or resetting.
4. When starting compressor for the first time after the reset with the power is ON.
5. When starting compressor for heating next to the suspension of defrosting.
6. When starting compressor next to the fault of switching over cooling / heating.
Set the lower limit frequency
3.3.4 3-minute Standby
Turning on the compressor is prohibited for 3 minutes after turning it off.
(Except when defrosting.)

3.3.5 Compressor Protection Function

When turning the compressor from OFF to ON, the upper limit of frequency is set as follows.
(The function is not activated when defrosting.)
FCG 1
FCG 2
FCG 3
TCG 1
TCG 2
TCG 3
38
20 class
Cooling
Heating
(Hz)
68
(seconds)
45
(Hz)
Frequency
FCG3
FCG2
FCG1
20 class
48
64
88
240
360
180
Hz for
seconds with any conditions 1 through 6 above.
25 class
Cooling
Heating
66
48
54
60
TCG2
TCG3
TCG1
25 class
35 class
55
55
70
70
85
85
150
120
180
200
300
470
SiENBE04-925_A
35 class
Cooling
Heating
48
48
70
(sec.)
Time
(R10540)
Unit
Hz
seconds
Function and Control