Outdoor Unit - RXL20G2V1B9
Step
2
Remove the 2 screws
and lift the top panel.
3
Remove the drip proof
plate.
4
Remove the 4 screws
and remove the
discharge grille.
184
Procedure
Drip proof plate
Discharge
grille
Top panel
(R7190)
(R7191)
(R7192)
(R7193)
SiENBE04-925_A
Points
„ The discharge grille has 4
hooks.
Removal Procedure