Daikin FTXL20G2V1B Service Manual page 174

Heat pump/indoor/outdoor units, inverter pair wall mounted type g-series
Hide thumbs Also See for FTXL20G2V1B:
Table of Contents

Advertisement

SiENBE04-925_A
Step
3. Remove the fan motor.
1
Remove the washer-
fitted nut of the outdoor
fan.
2
Remove the outdoor
fan.
3
Cut the clamp.
Removal Procedure
Procedure
Outdoor fan
D-cut
Outdoor Unit - RXL20G2V1B
„ The screw has reverse
winding.
„ Nut size: M6
(R7196)
„ When reassembling, align
mark of the outdoor fan
with D-cut section of the
motor shaft.
(R9330)
(R7198)
Points
10 mm
(R12236)
159