Daikin FTXL25J2V1B Operation Manual
Hide thumbs Also See for FTXL25J2V1B:

Advertisement

DAIKIN ROOM AIR CONDITIONER
MODELS
FTXL25J2V1B
FTXL35J2V1B
ATXL25J2V1B

Operation Manual

ATXL35J2V1B

Advertisement

Table of Contents
loading

Summary of Contents for Daikin FTXL25J2V1B

  • Page 1: Operation Manual

    DAIKIN ROOM AIR CONDITIONER MODELS FTXL25J2V1B FTXL35J2V1B ATXL25J2V1B Operation Manual ATXL35J2V1B...
  • Page 2: Table Of Contents

    CONTENTS READ BEFORE OPERATION Safety precautions ........2 Names of parts ..........4 Preparation Before Operation ....... 7 OPERATION AUTO · DRY · COOL · HEAT · FAN Operation ..........10 Adjusting the Air Flow Direction ....12 POWERFUL Operation ....... 14 ECONO Operation ........
  • Page 3: Safety Precautions

    • Do not attempt to repair, relocate, modify or reinstall the air conditioner by yourself. Incorrect work will cause electric shocks, fire etc. For repairs and reinstallation, consult your Daikin dealer for advice and information. • The refrigerant used in the air conditioner is safe. Although leaks should not occur, if for some reason any refrigerant happens to leak into the room, make sure it does not come in contact with any flame as of gas heaters, kerosene heaters or gas range.
  • Page 4: Installation Site

    • Do not block air inlets nor outlets. Impaired air flow may result in insufficient performance or trouble. • Do not stand or sit on the outdoor unit. Do not place any object on the unit to avoid injury, do not remove the fan guard. •...
  • Page 5: Names Of Parts

    Names of parts  Indoor Unit...
  • Page 6: Outdoor Unit

     Outdoor Unit Indoor Unit  1. Air filter 11. Indoor unit ON/OFF switch: (page 10.) • Push this switch once to start operation. 2. Titanium Apatite Photocatalytic Push once again to stop it. Air-Purifying Filter: • The operation mode refers to the following •...
  • Page 7: Remote Controller

     Remote Controller < > ARC433A87, A88 1. Signal transmitter: 8. FAN setting button: • It selects the air flow rate setting. • It sends signals to the indoor unit. 9. SWING button: 2. Display: • Ajusting the Airflow Direction. (page 12.) •...
  • Page 8: Preparation Before Operation

    Preparation Before Operation  To set the batteries Position + and 1. Slide the front cover to take it off. – correctly! 2. Set two dry batteries AAA.LR03 (alkaline). 3. Set the front cover as before. ATTENTION  About batteries •...
  • Page 9: Operation

    Preparation Before Operation  To operate the remote controller • To use the remote controller, aim the transmitter at the indoor unit. If there is anything to block signals between the unit and the remote controller, such as a curtain, the unit will not operate.
  • Page 10: Operation

     To set the clock 1. Press “CLOCK button”. is displayed. blinks. 2. Press “TIMER setting button” to set the clock to the present time. Holding down “ ” or “ ” button rapidly increases or decreases the time display. 3.
  • Page 11: Auto · Dry · Cool · Heat · Fan Operation

    OPERATION AUTO · DRY · COOL · HEAT · FAN Operation The air conditioner operates with the operation mode of your choice. From the next time on, the air conditioner will operate with the same operation mode.  To start operation 1.
  • Page 12: To Change The Air Flow Rate Setting

     To change the air flow rate setting 5. Press “FAN setting button”. DRY mode AUTO or COOL or HEAT or FAN mode Five levels of air flow rate setting from “ ” to “ ” plus “ ” “ ”...
  • Page 13: Adjusting The Air Flow Direction

    Adjusting the Air Flow Direction You can adjust the air flow direction to increase your comfort.  To adjust the horizontal blades (flaps) 1. Press “SWING button”. • “ ” is displayed on the LCD and the flaps will begin to swing. 2.
  • Page 14  To start COMFORT AIRFLOW operation 3. Press “COMFORT AIRFLOW button”. • The position of the flaps will change, preventing air from blowing directly on the occupants of the room. • “ ” is displayed on the LCD. • Airflow rate is set to “AUTO”. COOL/DRY...
  • Page 15: Powerful Operation

    POWERFUL Operation POWERFUL operation quickly maximizes the cooling (heating) effect in any operation mode. You can get the maximum capacity .  To start POWERFUL operation 1. Press “POWERFUL button”. • POWERFUL operation ends in 20 minutes. Then the system automatically operates again with the settings which were used before POWERFUL operation.
  • Page 16: Econo Operation

    ECONO Operation ECONO operation is a function which enables efficient operation by lowering the maximum power consumption value.  To start ECONO operation 1. Press “ECONO button”. • “ ” is displayed on the LCD.  To cancel ECONO operation 2.
  • Page 17: Timer Operation

    TIMER Operation Timer functions are useful for automatically switching the air conditioner on or off at night or in the morning. You can also use OFF TIMER and ON TIMER in combination.  To use OFF TIMER operation • Check that the clock is correct. If not, set the clock to the present time.
  • Page 18: To Use On Timer Operation

     To use ON TIMER operation • Check that the clock is correct. If not, set the clock to the present time (page 9.). 1. Press “ON TIMER button”. is displayed. blinks. 2. Press “TIMER Setting button” until the time setting reaches the point you like.
  • Page 19: Care And Cleaning

    CARE Care and Cleaning CAUTION Before cleaning, be sure to stop the operation and turn the breaker OFF. Units  Indoor unit, Outdoor unit and Remote controller 1. Wipe them with dry soft cloth.  Front panel 1. Open the front panel. •...
  • Page 20: Air Filter

    Filters 1. Open the front panel. (page 18.) Recess on • Hold the panel at the recesses on the main unit main unit (2 recesses on right and left sides) and lift it until it stops. 2. Pull out the air filters. •...
  • Page 21 [ Maintenance ] 1. Remove dust with a vacuum cleaner and wash lightly with water. 2. If it is very dirty, soak it for 10 to 15 minutes in water mixed with a neutral cleaning agent. 3. Do not remove filter from frame when washing with water. 4.
  • Page 22: Before A Long Idle Period

     Before a long idle period 1. Operate the “FAN only” for several hours on a fine day to dry out the inside. • Press “MODE selector button” and select “FAN”operation. • Press “ON/OFF button” and start operation. 2. After operation stops, turn off the breaker for the room air conditioner. 3.
  • Page 23: Troubleshooting

    TROUBLESHOOTING Troubleshooting These cases are not troubles. The following cases are not air conditioner troubles but have some reasons. You may just continue using it. Case Explanation Operation does not start soon. • This is to protect the air conditioner. You should wait for about 3 minutes.
  • Page 24: Check Again

    Check again. Please check again before calling a repair person. Case Check The air conditioner does not • Hasn’t a breaker turned OFF or a fuse blown? operate. • Isn’t it a power failure? (OPERATION lamp is off.) • Are batteries set in the remote controller? •...
  • Page 25: Call The Service Shop Immediately

    Call the service shop immediately. WARNING  When an abnormality (such as a burning smell) occurs, stop operation and turn the breaker OFF. Continued operation in an abnormal condition may result in troubles, electric shocks or fire. Consult the service shop where you bought the air conditioner. ...
  • Page 26: Fault Diagnosis

    Fault diagnosis. FAULT DIAGNOSIS BY REMOTE CONTROLLER In the ARC433 series, the temperature display sections on the main unit indicate corresponding codes. 1. When the TIMER CANCEL button is held down for 5 seconds, a “ ” indication flashes on the temperature display section.
  • Page 28 3P377621-2 2014.05...

This manual is also suitable for:

Atxl35j2v1bFtxl35j2v1bAtxl25j2v1b