SiENBE04-925_A
Step
5
Disconnect the
connector for swing
motors [S41].
6
Release the harness for
swing motors from the
hook.
7
Pull out the indoor heat
exchanger thermistor.
8
Remove the screw and
detach the earth wire.
Removal Procedure
Procedure
[S41]
Indoor heat exchanger thermistor
Earth wire
Points
(R7935)
(R7936)
„ Be careful not to lose the
clip of the thermistor.
Clip
(R7937)
(R7938)
Indoor Unit
(R11268)