Removal Of Drain Pan Heater - Daikin FTXL20G2V1B Service Manual

Heat pump/indoor/outdoor units, inverter pair wall mounted type g-series
Hide thumbs Also See for FTXL20G2V1B:
Table of Contents

Advertisement

Outdoor Unit - RXL25G2V1B
4.4

Removal of Drain Pan Heater

Procedure
Step
1. Remove the drain pan
heater.
1
Cut the clamp.
2
Remove the screw of
the mounting clamp.
3
Release the drain pan
heater ASSY from the
ditch between the
bottom frame and the
outdoor heat exchanger
ASSY.
Remove the wire spring
with long nose pliers.
226
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
(R9369)
Mounting
clamp
(R9350)
„ Take care not to cut your
finger by the fins of the
outdoor heat exchanger.
„ When reassembling, hang
Wire spring
the wire spring to the hair pin
cooling tube.
(R9351)
SiENBE04-925_A
Points
(R9748)
Removal Procedure