Removal Of Reactor / Partition Plate - Daikin FTXL20G2V1B Service Manual

Heat pump/indoor/outdoor units, inverter pair wall mounted type g-series
Hide thumbs Also See for FTXL20G2V1B:
Table of Contents

Advertisement

SiENBE04-925_A
2.6

Removal of Reactor / Partition Plate

Procedure
Step
1. Remove the reactor.
1
Remove the screw and
remove the reactor.
2. Remove the partition
plate.
1
Remove the 2 screws.
Removal Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Outdoor Unit - RXL20G2V1B
Preparation
Reactor
„ Remove the outer panels
according to the "Removal of
Outer Panels / Fan Motor".
„ Remove the electrical box
according to the "Removal of
Electrical Box".
(R7224)
(R7225)
Partition plate
(R7226)
Points
175