4.

INPUT/OUTPUT DATA

The radar(s) must be interconnected to the following type approved sensors:
Gyrocompass meeting the requirements of the IMO resolution A.424(XI).
EPFS meeting the requirements of the IMO resolution MSC.112(73).
SDME meeting the requirements of IMO resolution MSC.96(72).
The radar may be interconnected via HUB-3000 to other FURUNO processing
units having approved LAN ports.
4.1
Processor Unit
Input and output data are shown in the table below.
Input
Data
Heading signal
Speed signal
Navaid data
AIS signal
Alarm handling
signal
*: Data input cycle must be more than 40 Hz (high speed craft) or 20 Hz (conventional
ships).
Output
Data
Radar system data IEC 61162-1 Ed.4
TT data**
Alarm signal
**: The output sentence and baud rate can be set at the PC (See the Instruction Man-
ual). The mode ([TTM/TTD REFERENCE]) can be set at the [TT Preset] menu (See
page 3-8).
NOTICE
Specification
IEC 61162-2*
IEC 61162-1 Ed.4
IEC 61162-1 Ed.4 Position, time and
date, datum, course,
speed, wind, current,
depth, temperature,
NAVTEX, etc.
IEC 61162-2
Contact closure
IEC 61162-1 Ed.4
Specification
IEC 61162-1 Ed.4
IEC 61162-1 Ed.4
Contact closure
Contents
Input from alarm system
Input from alarm system
Contents
RSD, OSD
TTD, TTM, TLB
4 systems, Output con-
tents are selected by
menu.
Remarks
Remarks
4-1