2. WIRING
Case gasket OP24-28
The optional kit OP24-28 protects the connectors on the MC-3000C to waterproofing
standard IPX2.
Name
Case packing (serial)
1. Unfasten four binding screws to remove the cover from the adapter.
2. Peel the paper from the case gasket, then attach the case gasket to the reverse
side of the cover and the body unit as shown below.
3. Attach the cover to the MC-3000S body unit.
2-32
Case gasket (type: OP24-28, code no.: 001-169-970)
Type
24-014-2051
Cover
Case gasket
Cover (reverse side)
Case gasket
Code No.
Qty
100-367-880-10 2
Binding screw
Case gasket
Case gasket
Body unit
Remarks
For MC-3000S