Furuno FAR-3230S(-BB) Installation Manual page 63

Chart radar
Hide thumbs Also See for FAR-3230S(-BB):
Table of Contents

Advertisement

Input method (MC-3010A only)
Select the method of the analog data input, power voltage or power current.
Note 1: The input must not exceed the range of the input voltage, to prevent malfunc-
tion.
• Setting for voltage input: -10V to +10V or 0 to 10V (depending on the setting)
• Setting for contact input: Voltage 4mA to 20mA.
Note 2: When changing the input method, turn off the MC-3010A and on again to put
change in effect.
 Power voltage: Input the amount of power voltage change to the operational ampli-
fier.
Voltage
source
Load
 Power current: Pass the power current to the shunt resistor, 1kΩ/parallel (com-
bined resistance: 500Ω) to input the amount of voltage change at the both ends of
the resistor to the operational amplifier.
Current
source
Load
Pin #
Signal name
1
AN1_IN
2
AN1_GND
3
CURR1_JP1
4
CURR1_JP2
AN-IN
AN-GND
CURR-JP1
CURR-JP2
Jumper: open
AN- IN
AN- GND
CURR- JP 1
CURR- JP 2
Jumper short
Use NH connector
and AWG24 cable.
Connector J3
In/Out
Description
In
Analog 1 input
-
Analog 1 GND
-
Analog 1 input, power current/
voltage setting jumper 1
-
Analog 1 input, power current/
voltage setting jumper 2
AN +15V
+VS1
Vin
Opeamp
InGnd
- VS1
1kΩ 1% 0.5W×2
AN GND AN - 15V
AN +15V
+VS1
Vin
Opeamp
InGnd
- VS1
1kΩ 1% 0.5W×2
AN GND AN - 15V
Power voltage
TTYCS(LA)-1
Pin #3-#4: open Pin #3-#4: short
2. WIRING
+15V
+VS2
OutGnd
- VS2
GND
- 15V
+15V
+VS2
OutGnd
- VS2
GND
- 15V
Power current
2-35

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Far-3330sFar-3 seriesFar-3bb seriesFar-3230sFar-3230s-bb

Table of Contents