2. WIRING
How to fabricate the LAN cable
Fabricate the LAN cable (FR-FTPC-CY, DTI-C5E350 VCV), as shown below. (Wrap
both edges of the armor with vinyl tape.) Make sure the shield of the cable contacts
the shell of the modular plug.
Note: For a locally supplied LAN cable, expose the armor and clamp the armor with
the cable clamp.
1
Expose inner vinyl sheath.
4
approx. 9 mm
Fold back drain wire and
cut it, leaving 9 mm.
7
Using special crimping tool
MPT5-8 (PANDUIT CORP.),
crimp the modular plug.
Finally check the plug visually.
2-12
Armor
Cable jacket
Outer vinyl sheath
Wrap vinyl tape. (width: 20 mm)
2
Remove the outer sheath by
approx 25 mm. Be careful
not to damage inner shield
and cores.
5
approx. 11 mm
Straighten and flatten the
core in order and cut them,
leaving 11 mm.
1
30
55
Inner vinyl sheath
3
25 mm
6
Modular plug
8
approx. 9 mm
Fold back the shield, wrap it
onto the outer sheath and
cut it, leaving 9 mm.
Drain wire
Insert the cable into the modular
plug so that the folded part of
the shield enters into the plug
housing. The drain wire should
be located on the tab side of
the jack.

Hide quick links: