Blower - Jøtul GF 305 DV IPI Installation And Operation Instructions Manual

Direct vent gas stove
Hide thumbs Also See for GF 305 DV IPI:
Table of Contents

Advertisement

139843_A GF 305 DV IPI 8/17
Blower Kit 158023
 THIS BLOWER MUST BE ELECTRICALLY
GROUNDED IN ACCORDANCE WITH LOCAL
CODES OR, IN THE ABSENCE OF LOCAL
CODES, WITH THE CURRENT ANSI/NFPA 70,
NATIONAL ELECTRICAL CODE OR CSA C22.1-
CANADIAN ELECTRICAL CODE.
 THIS UNIT IS SUPPLIED WITH A THREE-
PRONG (GROUNDING) PLUG FOR
PROTECTION AGAINST SHOCK HAZARD
AND SHOULD BE PLUGGED DIRECTLY INTO
A PROPERLY GROUNDED THREE-PRONG
RECEPTACLE. DO NOT CUT OR REMOVE THE
GROUNDING PRONG FROM THE PLUG.
 ALWAYS DISCONNECT THE POWER SUPPLY
WHEN PERFORMING ANY SERVICE ON THE
APPLIANCE.
Contents

• Blower

• Blower Shroud
• IFC Blower wire harness
• Remote Transmitter
• M8 x 15 mm hex hd bolts 2
• #8 x 12 sheet metal screws, 2
The blower functions are controlled by the Remote
Transmitter hand set which is included with the kit.
See Remote Control initialization and operation
instructions on pages 30-33.
1. Orient the blower housing with the outlet to the rear
and the air inlet facing down. Engage the housing
with the two pegs, (A) in the center of the cabinet
floor. Fig. 11.6.
2. Connect the blower power lead (B) to the IFC board
terminal labelled "FAN". See Fig. 11.7.
3. Connect the blower ground lead to the ground
terminal at the front of the IFC using the nut
provided on the board. Fig. 11.7.
4. Attach the Blower Shroud to the side flanges at the
rear of the cabinet floor using the two #8 X 12 mm
sheet metal screws. See Fig. 11.8, (A).
Attach the upper flange of the shroud to the stove
bottom plate using the two, M8 x 15 mm hex bolts
(B) from this kit.
22
Figure 11.6.
Engage the blower housing on the compartment floor pegs.
Tools Required
• 13 mm open
end wrench
or socket
• 7mm nut driver
• Safety glasses
• Work gloves
Figure 11.7. Blower & Lamp Terminal Connections.
5. The power cord (C) is routed to the right rear stove leg
6. Connect the power cord to the nearest house current
A
behind the Right Utility Cover. It may be removed to
accommodate installation requirements as necessary.
See fig. 11.9 and fig. 17.8, page 43.
outlet.
A
C
A
B
GRD