Remote Control; Remote Control Functions - Jøtul GF 305 DV IPI Installation And Operation Instructions Manual

Direct vent gas stove
Hide thumbs Also See for GF 305 DV IPI:
Table of Contents

Advertisement

Remote Control Functions

Pilot Mode
Set the stove switch to CPI mode for Proflame 2
remote control. The IPI/CPI functionality will be
controlled by the remote transmitter.
Burner Control
Set the stove burner switch to ON for Proflame 2

remote control.

OFF - Turns off both remote and manual burner
functionality. Switch to OFF when the stove will not be
used for an extended period of time.
Remote Transmitter
The Transmitter features a simple button layout and
informative display screen. See fig. 15.1.
LCD DISPLAY - graphically indicates temperature
settings and status of the Thermostat, Burner, Fan, and
Accent Lamp.
ON / OFF Key - controls Burner, Fan, and Lamp functions.
THERMOSTAT Key - Used to set either Manual or
Thermostatic Control and index through thermostatic
functions.
UP / DOWN Arrow Key - Selects thermostat
temperature range, fan speed, and flame height.
MODE Key - used to select the component to be
controlled: CPI/IPI, Burner, Fan, and Accent Lamp.
The Wall Mount Bracket can be used for convenient
Transmitter storage.
Transmission
Thermostat
ON / OFF / SMART
Set Point
Temperature Level State
Burner
Modulation
Fan Modulation
Figure 15.1. Remote transmitter display data.
°F
°C
OFF
ON
SMART
MAX
MAX
Lamp Modulation
Initializing the System
1. Press the Controls Access Door to release its magnetic
catch and swing the panel down.
Switch the Burner to OFF. See fig. 15.1, page 31.
2. Install three AAA batteries into the Transmitter
handset.
3. Press the red or black button on the right front
corner of the IFC board, just behind the switch plate.
The board will "beep" three times and a yellow LED
indicates a 10-second synchronization time limit.
4. Within the 10-second time frame, push the ON button
on the Transmitter. The IFC will "beep" three or four
times to indicate that it has acknowledged the
transmitter command and sets to the particular code
of that Transmitter.
5. After initialization, the burner switch must be placed
in the ON position and Pilot Mode switch placed in CPI.
The remote can then be used to control the burner.
To return to full Manual functionality, hold the red or
black initialization button down until it "beeps" three
or four times and the yellow LED illuminates. Within
10 seconds, push the button again until it signals the
acknowledgement.
Remote
transmitter
function keys.
Child Safety Lock-out
Low Battery Alarm
Room
Temperature
CPI Mode
AUX
(Not Applicable)
Split Valve
139843_A GF 305 DV IPI 8/17
Blue LCD Screen
ON/OFF Key
THERMOSTAT Key
UP/DOWN Key
MODE Key
33