Manual Operation

Familiarize yourself with the controls of the GF 305 DV
IPI and be sure that anyone else using the appliance is
also familiar with the controls and operation procedures.
Always follow the Lighting Instructions on the inside back
cover of this manual and also located on the inside the
Controls Access Panel.
This appliance is equipped with an ignition device
that lights the pilot automatically. Do not try to light the
pilot by hand.
1. Set the Burner switch to OFF. See fig. 15.1.
2. If a wall thermostat is used, set it to the lowest
temperature.
3. Connect the stove to 120VAC house current with the
power cord supplied.
4. Set the Pilot Mode:
• CPI for continuous pilot operation.
• IPI for intermittent pilot operation.
Control Switches
Figure 15.1. GF 305 DV IPI Controls Compartment.
5. Once the pilot is lit, burner operation is controlled by the
rocker switch located on the front panel.
• ON / OFF - use for manual control of the burner.
• T-STAT - use for optional wall thermostat.
6. Flame intensity can be adjusted by turning the Valve
Regulator control knob.
Gas Control Valve
Manual
Regulator
Function LED
Battery Box
139843_A GF 305 DV IPI 8/17
Integrated
Fireplace
Contol
31