Premium Upgrade Kits - Jøtul GF 305 DV IPI Installation And Operation Instructions Manual

Direct vent gas stove
Hide thumbs Also See for GF 305 DV IPI:
Table of Contents

Advertisement

139843_A GF 305 DV IPI 8/17
11. Premium Upgrade Kit
#158030 - NG
#158031 - LP
Kit Contents:
• Flame Control Kit (NG, 158032 / LP, 158033)
• Accent Lamp Kit 157469
• Blower Kit with Multifunction Remote 158023
READ THESE INSTRUCTIONS BEFORE BEGINNING
INSTALLATION. INSTALL EACH COMPONENT IN THE ORDER
PRESENTED HERE.
EXCEPT AS NOTED, ALL INSTRUCTIONS ARE
ORIENTED FACING THE FRONT OF THE STOVE.
Flame Control Installation
1. Using a Torx T-20 screwdriver, remove the two screws
from the front of the manual regulator and remove
those components as shown in fig. 11.3.
2. Confirm the appropriate fuel type by the label on the
Flame Control motor. Install the motor using the new
screws included with the kit.
3. Connect the wire harness to terminal (M) on the near
side of the IFC board, fig. 11.3.
4. If appropriate, follow the instructions for fuel
conversion beginning on page 15.
SEE PAGES 32-35 FOR REMOTE CONTROL OPERATION.
Figure 11.3. Flame Control Motor installation.
20
Accent Lamp Kit 157469
INSTALL THE LAMP BEFORE CONNECTING THE
STOVE TO VENTING.
Contents:
1. Lamp Box
2. Wire Harness
3. Lens
4. Gasket
5. Light Deflector Plate
1. Lift the Top Plate from the stove.
2. Refer to figs. 11.4 and 11.4a. Remove the two M8 hex
head bolts (A), nuts (B), and steel Lamp Cover Plate
from the firebox top using a 10 mm socket wrench.
Discard the cover plate.
3. Install the Gasket, Lens, and Lamp Box over the opening
on the firebox using the two bolts (A) previously
removed.
4. Using the nuts previously removed, secure the Light
Shade plate to the bolts on the underside of the lamp
assembly inside the firebox. NOTE: ORIENT THE SHADE
FLANGE TO THE FRONT OF THE STOVE.
5. Route the lamp wire harness over and down through
the right rear Air Duct as shown in Fig. 11.5.
Connect the harness (A) to the terminal labelled
"Lamp" on the right side of the IFC board. See fig. 11.7
on page 22.
6. Replace the Top Plate.
To IFC "M"
Terminal
Figure 11.4. Remove the Lamp Cover Plate.
Tools Required:
• 13 mm wrench
• Safety goggles
• Work gloves
Lamp Cover
Plate

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents