Table G-4 High-Speed Counters HSC0, HSC3, HSC4, and HSC5
Mode
Mode
I0.0
I0.1
0
Clk
1
Clk
2
3
Clk
Direction
4
Clk
Direction
5
6
Clk Up
Clk Down
7
Clk Up
Clk Down
8
9
Phase A
Phase B
10
Phase A
Phase B
11
Table G-5 High-Speed Counters HSC1 and HSC2
Mode
Mode
I0.6
I0.7
0
Clk
1
Clk
2
Clk
3
Clk
Direction
4
Clk
Direction
5
Clk
Direction
6
Clk Up
Clk Down
7
Clk Up
Clk Down
8
Clk Up
Clk Down
9
Phase A
Phase B
10
Phase A
Phase B
11
Phase A
Phase B
G-4
HSC0
HSC3
I0.2
I0.1
Clk
Reset
Reset
Reset
Reset
HSC1
I1.0
I1.1
Reset
Reset
Start
Reset
Reset
Start
Reset
Reset
Start
Reset
Reset
Start
HSC4
I0.3
I0.4
I0.5
Clk
Clk
Reset
Clk
Direction
Clk
Direction
Reset
Clk Up
Clk Down
Clk Up
Clk Down
Reset
Phase A
Phase B
Phase A
Phase B
Reset
HSC2
I1.2
I1.3
I1.4
Clk
Clk
Reset
Clk
Reset
Clk
Direction
Clk
Direction
Reset
Clk
Direction
Reset
Clk Up
Clk Down
Clk Up
Clk Down
Reset
Clk Up
Clk Down
Reset
Phase A
Phase B
Phase A
Phase B
Reset
Phase A
Phase B
Reset