Assignment Of The Isolating Transformer To The Ui Modules - Siemens SIMODRIVE 611 digital Configuration Manual

Drive converters
Hide thumbs Also See for SIMODRIVE 611 digital:
Table of Contents

Advertisement

Aotewell Ltd
05.08
05.01
7.3.4
Table 7-9
Nominal rated power
Power loss, max.
Vector group
Short- -circuit voltage uk [%]
Degree of protection to
DIN EN 60529 (IEC 60529)
Humidity rating EN 60721- -3- -3
Permiss. ambient temperature
S
Operation
S
Storage/transport
Approx. weight for
S
Degree of prot. IP 00
S
Degree of prot. IP 20/23
Dim. (L x W x H) approx.
Max. conn., secondary
Input voltage, 3- -ph. 575 V - - 500 V - - 480 V AC ± 10%; 50 Hz - - 10% to 60 Hz + 10%
Rated input current
Max. conn., primary
Order No. according to Catalog
PD10
Input voltage, 3- -ph. 440 V - - 415 V - - 400 V AC ± 10%; 50 Hz - - 10% to 60 Hz + 10%
Rated input current
Max. conn., primary
Order No. according to Catalog
PD10
Input voltage, 3- -ph. 240 V - - 220 V - - 200 V AC ± 10%; 50 Hz - - 10% to 60 Hz + 10%
Rated input current
Max. conn., primary
Order No. according to Catalog
PD10
1)
For degree of protection IP 23, a 10% power derating must be taken into account
2) Not degree of protection IP 20
© Siemens AG 2008 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) - - 05/2008 Edition
HongKong|UK|China
www.aotewell.com

Assignment of the isolating transformer to the UI modules

Matching transformers with separate windings for 50 Hz/60 Hz line supplies
UI module
[kVA]
8.2
[W]
520
YYn0 neutral point N can only be loaded with maximum 10%!
≤ 10
S
Degree of protection IP 00: V - -- -> Order No. 0
S
Degree of protection IP 20: V - -- -> Order No. 8
S
Degree of protection IP 23: V - -- -> Order No. 2
Class 3K5 condensation and formation of ice excluded
- -25 to +40, for power derating up to +55
_C
- -25 to +80
_C
[kg]
55
[kg]
65
[mm]
360 x 268 x 320
2
[mm
]
6
[A]
10.5
2
[mm
]
6
4AU36 95- -0SB0V- -0CN2
[A]
12.5
2
[mm
]
6
4AU36 95- -0SB1V- -0CN2
[A]
25.5
2
[mm
]
6
4AU36 95- -0SB2V- -0CN2
Note
UI modules can be operated on TN line supplies from 360 V (with derating!) to
480 V without a matching transformer.
sales@aotewell.com
7.3 Line supply fuses, transformers and main switch
UI module
2)
5 kW
10 kW
15.7
650
70
95
420 x 262 x 370
6
20
6
4AU39 95- -0SA3V- -0CN2
23.5
16
4AU39 95- -0SA4V- -0CN2
47
16
4AU39 95- -0SA5V- -0CN2
Industry Automation
7 Line Supply Connection
UI module
2)
28 kW
47
1200
1)
200
216
480 x 267 x 420
35
58
35
4BU47 95- -0SC3V- -0C
69.5
35
4BU47 95- -0SC4V- -0C
138.5
70
4BU47 95- -0SC5V- -0C
+86-755-8660-6182
7
7-217